the use and maintenance:, it is recommended to use unit with the designation of personnel responsible for, use and maintenance, - every year
Time of preventive maintenance is solenoid pneumatic valve and reliable work and the best way to longevity.
Solenoid pneumatic valve inside the following kinds of situation, obstruct electromagnetic pneumatic valve normal work and shorten life.
(1), the use of medium change in [2] over the rust, (3), air compressor oil oxidation, carbon grain of tar and other sundry, mixed with the pipe.
Pipeline there are impurities such as dust dirt, solenoid pneumatic valve is installed, or again after stopping for a long time when in operation, please try access into the medium action several times working properly rear can officially use pneumatic valve, steam again after long time stop running, should be no net condensate try several times, after working properly rear can put into operation.
, before maintenance, must cut off the power and discharge pressure of medium.
, coil components should not open it, open solenoid pneumatic valve and clean, can use kerosene ` solution such as trichloroethylene.
But should pay attention to the rubber parts may dissolve, so want to change it.
When cleaning, apart, all parts are to recover installed in sequence.
Equipped with wearing parts, my company, please follow the instructions when necessary and declared in order.
And disassembly sequence, wearing parts and other matters have an unknown place, please consult technical department (
Hotline: -
)
Reading the use of the product manual carefully before installation, check whether the product completely conform to the requirements of the use, familiar with the key points of installation, ready for work.
When installing electromagnetic solenoid coil up, and keep the vertical position, the arrow or mark in the solenoid pneumatic valve should be consistent with the pipe flow, shall not be installed in places with splashing water or water leakage.
Over before use.
MPa pressure pipe fully flush, the metal powder in the pipeline sealing material residues, completely removed rust scale, etc;
Working medium of pneumatic valve should be clean and no impurity particles, suggest to install filters before the pneumatic valve, steam piping installation hydrophobic pneumatic valve;
Electromagnetic pneumatic trims on the surface of the dirt and filters, must be clean regularly.
In the electromagnetic pneumatic valve failure occurs, in order to timely isolation solenoid pneumatic valve, and ensure the normal operation of the system, the best install bypass device.
As shown in figure (
A)
。
When the solenoid pneumatic valve installed in the branch, the calibre of the solenoid pneumatic valve should be smaller than main line of the pneumatic valve diameter, as shown in figure (
2)
Shunt device.
Note: the branch on the pneumatic valves must be closed.
Don't install the pneumatic valve in pipe dips, in order to avoid steam condensation water, impurities, such as the precipitation in the pneumatic valve and interfere with the action.
Normal electromagnetic pneumatic valve cannot be used in inflammable and explosive dangerous places.
In the pipes under rigid, recommend to use pneumatic valve and pipe bracket, in case of electromagnetic vibration caused by pneumatic valve work.
Electromagnetic air valve on the pipeline before and after the need to install pressure gauge, in order to observe the pipe pressure.
故障分析与排除方法: