It is a 1" Normal Close Water solenoid valve.Water solenoid valve has closed cavity, in a different location to open a hole, each hole leads to different tubing, cavity valve is among, both sides are two electromagnets, which face the magnet coil electricity body will be attracted to which side, by controlling the movement of the valve body blocked or leakage of different discharge of oil hole, and the oil hole is always open, hydraulic fluid will enter the different oil drain, and then through the oil pressure to push the cylinder piston, piston drives the piston rod, piston rod drive mechanism.Thus the mechanical motion is controlled by controlling the current of the electromagnet.
◈Model: 2W160-10 2W160-15 2W200-20 2W250-25 2W350-35 2W400-40 2W500-50 Joint Pipe Bore:G1/8;G1/4;G3/8;G1/2;G1;G2.
◈Operation Fluid Viscosity:20 CST (Below)
◈Working-pressure:0~2.0MPa
◈Max. Pressure Resistance:3.5MPa
◈Operating Temperature Range:-5~+80℃
◈Standard voltage:AC220,AC110V,AC24V,DC24V,DC12V.
◈Voltage Range:±10%
◈Material of Body:2W: Brass ; 2S: Stainless Steel
◈Material of Oil Seal:NBR, EPDMVITON / NBR, EPDM or VITON
◈Type:Normal Close Type ; Normal Open Type
◈Motion Pattern:Direct Drive Type
◈Working Medium: Air, Water, Oil, Gas,Fuel
◈ Water solenoid valve is suitable for water or liquid as the working medium, can automatically control or remote control of water, oil, liquid and other working medium pipeline on and off.Because this valve USES the rubber seal, therefore to the working medium cleanliness greatly reduces, has opens and closes quickly, the reliability high characteristic.
◈The diaphragm structure with direct motion is adopted to start without pressure, which expands its application field
◈The use of flat diaphragm structure opening and closing reliable, and enhance the service life of the product.
◈The use of laminated coils improves the safety of the product in a wide variety of environments.
Installation
◈Solenoid valve is generally directional, can not be installed in reverse, usually on the valve body with "→" to indicate the direction of medium flow, installation should be in accordance with the direction of"→ "instructions
◈Manual shut-off valve should be added before and after the solenoid valve, and a bypass should be set to facilitate the maintenance of solenoid valve in case of failure.
◈Take care not to use too much sealing material when taking over.
◈Try not to let the solenoid valve in the power state for a long time, It will reduce the coil life or even burn out the coil, that is to say, often open, often closed solenoid valve can not be used interchangeably.