Electromagnetic pulse pneumatic valve installation using matters needing attention
by:AIRWOLF2021-01-16
best installation method, the electromagnetic pulse pneumatic valve is perpendicular to the horizontal line, coil up.
In the premise does not allow, promised to plus or minus ° incline.
Otherwise, can't guarantee the normal use.
Pneumatic valve, electromagnetic parameters should be consistent with the actual use requirements on the nameplate.
Pneumatic valve, electromagnetic pneumatic the arrow on the valve body shall be consistent with the medium flow direction.
, in order to ensure the normal use of pneumatic valve, please add oil and water separator before the solenoid pneumatic valve.
, in the dangerous environment to prevent electric spark may cause the accidents such as explosion, explosion-proof solenoid pneumatic valve should be used.
Before installation, please thoroughly purge gas bag and pipeline, to avoid foreign object damage caused electromagnetic pneumatic diaphragm valve failure.
, failure occurs when the solenoid pneumatic valve, in order to timely isolation and convenient for maintenance, it is suggested that install by-pass (
The bypass)
Device.
, electromagnetic pulse pneumatic valve not installed, can be stored in ~ ℃, relative humidity % or less, but the indoor erosion neutral, as far as possible avoid in open air.
, when unpacking the case should be used to check the package insert, the factory certificate, packing list is complete.
According to the listing again to check whether the product name, model, control plaque whether matches the purchase order.
If the defect or not, should be timely and contact idea.