Electric soft sealing pneumatic valve rely on electric actuator motor to drive the pneumatic valve pneumatic valve shaft rotation, pneumatic valve shaft plate rotates 90 ° to realize the pneumatic valve opening and closing, can be done using truncation and adjust flow. Electric soft seal pneumatic valve electric actuator with ultimate end limit switch, can automatically cut off the circuit to the finish line and at the same time in order to ensure the engineering safety, electric soft seal pneumatic valve is equipped with electrical overload protection device and light instructions. Electric soft sealing pneumatic valve failure and handling method generally have the following kinds:


1. Pneumatic valve packing leakage


reasons: (1) packing aging is serious. (2) gland bolts not tight or loose.


the solution: (1) change the new packing. (2) tighten gland bolts evenly.


2. Leakage of end cover a


reasons: (1) bolt not tighten. (2) o-rings damaged.


the solution: (1) check whether the bolt is loose, tighten it. (2) replace o-rings.



3. Leakage of sealing surface in


reasons: (1) plate close does not reach the designated position. (2) the sealing surface dirt, lead to shut down is lax. (3) sealing surface damage.


the solution: (1) to adjust the screw on the electric pneumatic valve electric actuator, turn off the board in place. (2) clean the sealing surface dirt. (3) to repair the damage of seal face.


4. Electric actuator is not flexible pneumatic valve can not be normal opening and closing operation


reasons: (1) the tight packing pressure. (2) the packing gland is not tightened in place, tilt. (3) excessive device failure damage.


the solution: (1) too tight, the packing gland don't relax appropriately. (2) correction of packing gland verticality. (3) change the new transition device.


5. The end of the opening and closing motor did not stop or incomplete open-close


reasons: (1) limit switch failure or overload protection device is not allowed. (2) limit switch action early or too late response.


the solution: (1) change the limit switch or make adjustment to overload device, ensure the accuracy. (2) adjust the reaction velocity of limit switch.